Direct measurement of the lunar dayside surface potential and screening length has been made by the suprathermal ion detector experiment (Side) near the terminator. In a region 20¿--30¿ from the terminator at the Apollo 14 and 15 sites the surface potential is found to be approximately 50 V negative, and the screening length to be about 1 km. This value of the screening length is more than 2 orders of magnitude greater than the solar wind 'Debye' length. The strong negative surface potential in this region may be due to enhanced temperature and density of the solar wind plasma. |