Measurements have been completed for eight different poroelastic moduli of water-saturated Berea sandstone and Indiana limestone as a function of confining pressure and pore pressure. The poroelastic moduli for Indiana limestone are generally consistent to ¿10%, which was verified by a formal inversion procedure for independent moduli from the eight measurements. For Indiana limestone, best fit values were drained bulk modulus, 21.2 GPa; the undrained bulk modulus, 31.7 GPa; drained Poisson's ratio, 0.26; undrained Poisson's ratio, 0.33; and pore pressure buildup coefficient, 0.47 at 20--35 MPa effective stress. The poroelastic moduli for Berea sandstone are generally consistent to ¿20%. The greater inconsistency is most likely caused by the nonlinear variation of the moduli at different strains. For Berea sandstone, best fit values were drained bulk modulus, 6.6 GPa; undrained bulk modulus, 15.8 GPa; drained Poisson's ratio, 0.17; undrained Poisson's ratio, 0.34; and pore pressure buildup coefficient, 0.75 at 10 MPa effective stress. ¿ American Geophysical Union 1995 |