Thottappillil et al. 1998
Thottappillil, R., Uman, M.A. and Rakov, V.A. (1998). Treatment of retardation effects in calculating the radiated electromagnetic fields from the lightning discharge. Journal of Geophysical Research 103: doi: 10.1029/97JD02941. issn: 0148-0227.

The analytical treatment of retardation effects in calculating lightning electromagnetic fields far from the source has often involved the use of a so-called F factor. The literature concerning the F factor in the lightning field equations is often confusing and sometimes in error. The aim of this paper is to clarify, to correct when needed, and to extend previous views of the F factor by considering and consolidating the various situations, both mathematically and physically, in which this factor can occur. The F factor arises because of the retardation effects occurring when the distance to the observer from a point on a propagating current is changing with time. In this paper we (1) discuss the various situations in which the F factor can arise, such as in the determination of the radiating channel length seen by the observer, in the calculation of fields due to a propagating current wave up or down the discharge channel, and in the calculation of fields due to a propagating current discontinuity extending the channel upward; (2) give a unifying physical interpretation for this factor; and (3) show that the retardation effects in calculating lightning fields can be accounted for without the explicit use of an F factor. Relative to item 2 above, we will show that for simple return-stroke models like the transmission line (TL) and traveling current source (TCS) models, in which the current at one point on the channel appears at another point at another time, the F factor associated with current behind the front can be interpreted physically as the ratio of the apparent propagation speed (upward or downward) of the current wave seen by a distant observer to its actual speed. In the TL model, a current wave moves upward at speed v, the same speed as that of the front, and the F factor is given by <1-(&ngr;/c)cos &thgr;>-1, where &thgr; is the angle between the direction of propagation of the source and the line joining the source point and the field point (observer), and c is the speed of light in vacuum. In the TCS model, a current wave moves downward at a speed equal c, and the F factor is given by <1+cos &thgr;>-1. The F factor associated with an upward propagating current discontinuity can always (in any model) be interpreted physically as the ratio of the apparent propagation speed of the discontinuity to its actual speed and is given by the same expression as for the F factor for the upward propagating current wave in the TL model. ¿ 1998 American Geophysical Union

BACKGROUND DATA FILES

Abstract

Keywords
Meteorology and Atmospheric Dynamics, Atmospheric electricity, Meteorology and Atmospheric Dynamics, Lightning
Journal
Journal of Geophysical Research
http://www.agu.org/journals/jb/
Publisher
American Geophysical Union
2000 Florida Avenue N.W.
Washington, D.C. 20009-1277
USA
1-202-462-6900
1-202-328-0566
service@agu.org
Click to clear formClick to return to previous pageClick to submit