EarthRef.org Reference Database (ERR)
Development and Maintenance by the EarthRef.org Database Team

Detailed Reference Information
Apel et al. 1998
Apel, E.C., Calvert, J.G., Riemer, D., Pos, W., Zika, R., Kleindienst, T.E., Lonneman, W.A., Fung, K., Fujita, E., Shepson, P.B., Starn, T.K. and Roberts, P.T. (1998). Measurements comparison of oxygenated volatile organic compounds at a rural site during the 1995 SOS Nashville Intensive. Journal of Geophysical Research 103: doi: 10.1029/98JD01753. issn: 0148-0227.

Simultaneous measurements of oxygenated volatile organic compounds (OVOCs) by four independent research groups at the Youth Incorporated (YI) site during the 1995 Southern Oxidants Study Nashville Intensive, between July 4 and 30, 1995, provided a unique opportunity to compare results from different techniques. 2,4-Dinitrophenylhydrazine (DNPH) coated C18 (C18AtmAA) and Si-Gel (Si-GelMTE) cartridges were compared with each other and with two sorbent-based preconcentration gas chromatographic (GC) techniques coupled with mass spectrometric (MS) detection (GC/MSUM and GC/MSPU) or flame ionization detection GC/FIDUM. The experiment consisted of both a laboratory (part A) and an ambient air comparison (part B). In part A of the study, standard mixtures of OVOCs were diluted in a flowing gas stream of humidified, purified air, both with and without addition of O3, and distributed to participant's instrumentation. Concentrations were compared with the expected values based on known cylinder concentrations and dilution factors. In part B of the study, the instruments sampled ambient air from a common glass manifold. Species intercompared were formaldehyde, acetaldehyde, acetone, and propanal. The C18AtmAA data were typically higher than the Si-GelMTE data for the four intercompared compounds, and possible explanations are given. Agreement between the cartridge systems and the GC/MS, GC/FID systems for comeasured compounds was poorer than expected but improved towards the end of the experiment. The GC/MS systems tracked each other well for acetone, but there were differences in the absolute concentration values. These results show that improvements in the accuracy and comparability of techniques should be of high priority. ¿ 1998 American Geophysical Union

BACKGROUND DATA FILES

Abstract

Keywords
Atmospheric Composition and Structure, Instruments and techniques
Journal
Journal of Geophysical Research
http://www.agu.org/journals/jb/
Publisher
American Geophysical Union
2000 Florida Avenue N.W.
Washington, D.C. 20009-1277
USA
1-202-462-6900
1-202-328-0566
service@agu.org
Click to clear formClick to return to previous pageClick to submit