EarthRef.org Reference Database (ERR)
Development and Maintenance by the EarthRef.org Database Team

Detailed Reference Information
Rosell-MelHemond et al. 2001
Rosell-MelHemond, A., Bard, E., Emies, K., Grimalt, J., Muller, P., Schneider, R., Bouloubassi, I., Epstein, B., Fahl, K., Fluegge, A., Freeman, K., Goñi, M., Gunter, U., Hartz, D., Hellebust, S., Herbert, T., Ikehara, M., Ishiwatari, R., Kawamura, K., Kenig, F., De Leeuw, J., Lehman, S., Mejanelle, L., Ohkouchi, N., Pancost, R.D., Pelejero, C., Prahl, F., Quinn, J., Rohtani, J.-F., Rostek, F., Rullkotter, J., Sachs, J., Blanz, T., Sawada, K., Schulz-Bull, D., Sikes, E., Sonzogni, C., Ternois, Y., Versteegh, G., Volkman, J. and Wakeham, S. (2001). Precision of the current methods to measure the alkenone proxy UK'37 and absolute alkenone abundance in sediments: Results of an interlaboratory comparison study. Geochemistry Geophysics Geosystems 2. doi: 10.1029/2000GC000141. issn: 1525-2027.

Measurements of the UK'37 index and the absolute abundance of alkenones in marine sediments are increasingly used in paleoceanographic research as proxies of past sea surface temperature and haptophyte (mainly coccolith-bearing species) primary productivity, respectively. An important aspect of these studies is to be able to compare reliably data obtained by different laboratories from a wide variety of locations. Hence the intercomparability of data produced by the research community is essential. Here we report results from an anonymous interlaboratory comparison study involving 24 of the leading laboratories that carry out alkenone measurements worldwide. The majority of laboratories produce data that are intercomparable within the considered confidence limits. For the measurement of alkenone concentrations, however, there are systematic biases between laboratories, which might be related to the techniques employed to quantify the components. The maximum difference between any two laboratories for any two single measurements of UK'37 in sediments is estimated, with a probability of 95 percent, to be < 2.1 degrees C. In addition, the overall within-laboratory precision for the UK'37 temperature estimates is estimated to be < 1.6 degrees C (95 percent probability). Similarly, from the analyses of alkenone concentrations the interlaboratory reproducibility is estimated at 32 percent, and the repeatability is estimated at 24 percent. The former is compared to a theoretical estimate of reproducibility and found to be excessively high. Hence there is certainly scope and a demonstrable need to improve reproducibility and repeatability of UK'37 and especially alkenone quantification data across the community of scientists involved in alkenone research.

BACKGROUND DATA FILES

Abstract

Keywords
alkenones, UK'37, interlaboratory comparison, organic geochemistry, instruments and techniques, paleoceanography, organic marine chemistry
Journal
Geochemistry Geophysics Geosystems
Publisher
American Geophysical Union
2000 Florida Avenue N.W.
Washington, D.C. 20009-1277
USA
1-202-462-6900
1-202-328-0566
service@agu.org
Click to clear formClick to return to previous pageClick to submit