Detailed Reference Information |
Goto, S., Kinoshita, M., Schultz, A. and Von Herzen, R.P. (2003). Estimate of heat flux and its temporal variation at the TAG hydrothermal mound, Mid-Atlantic Ridge 26°N. Journal of Geophysical Research 108: doi: 10.1029/2001JB000703. issn: 0148-0227. |
|
From August 1994 to March 1995, three 50-m-high vertical thermistor arrays designated Giant Kelps (GKs) were deployed around the central black smoker complex (CBC) at the TAG hydrothermal mound, Mid-Atlantic Ridge (26¿08'N, 44¿49'W). These were designed to monitor the temporal variability of the vertical temperature distribution in the hydrothermal plume. One small high-temperature probe Hobo was also deployed in one of the black smoker vents of CBC. Over the observation period, two typical characteristics are recognized in plume temperatures measured with GKs: (1) the amplitudes of temperature anomalies decrease with increasing height above the top of CBC; (2) maximum temperature anomalies on the upper thermistors occurred periodically and nearly simultaneously across the array about every 6 hours. Conversely, maximum temperature anomalies on the lower thermistors occurred periodically every 12 hours, indicating that the location of the plume discharged from CBC was forcibly moved by the change in direction of tidally modulated current flow. The heat flux from CBC was estimated from temperatures measured by GKs based on a model of buoyant hydrothermal fluid rising in a stable, stratified density environment. The estimated heat flux from CBC gradually decreases from about 86 to 55 MW over the ~7 months of measurement, with a mean rate of decrease of 0.17 MW d-1. Since the black smoker effluent temperature measured with Hobo was almost stable over the measurement period, a plausible cause of the decrease is a reduction in the volume of hydrothermal fluid provided to the CBC (in which case the estimated mean rate of decrease in volume flux of CBC is 8.9 m3 d-1). Estimated heat flux, temperature anomalies observed by Hobo, and diffuse flow and subbottom temperature anomalies recorded by other long-term monitoring instruments before, during, and after ODP Leg 158 indicate that the drilling probably affected the fluid flow pattern within the mound but had little effect on the total heat flux from CBC. |
|
 |
 |
BACKGROUND DATA FILES |
|
 |
Abstract |
|
 |
|
|
|
Keywords
Marine Geology and Geophysics, Heat flow (benthic) and hydrothermal processes, Marine Geology and Geophysics, Instruments and techniques, Oceanography, Biological and Chemical, Hydrothermal systems, Tectonophysics, Hydrothermal systems, Volcanology, Hydrothermal systems |
|
Publisher
American Geophysical Union 2000 Florida Avenue N.W. Washington, D.C. 20009-1277 USA 1-202-462-6900 1-202-328-0566 service@agu.org |
|
|
 |