F Status N Database Field Variable Name Units Required Description
R 1 Expedition Name er_expedition_name Text Required Name for seagoing or land expedition Examples are: AVON02MV
R 2 Location Name er_location_name Text Required Name for location or drill site Examples are: San Francisco Volcanic Province, Site 801
R 3 Formation Name er_formation_name Text Required Name for formation Examples are: Bluebird Formation
R 4 Member Name er_member_name Text Required Name for member Examples are: Glasshound Member
R Deleted 5 Section Name er_section_name Text Required Name for section or core Examples are: Berkeley Lava Flows, 810C, 1129D
R 6 Site Name er_site_name Text Required Name for site Examples are: Bas123a
R 7 Sample Name er_sample_name Text Required Name for sample Examples are: Bas123a-01
R 8 Specimen Name er_specimen_name Text Required Name for specimen Examples are: Bas123a-01x
R Reclassified 9 Fossil Name er_fossil_name Text Recommended Name for fossil Examples are: AMM43-03
R Reclassified 10 Mineral Name er_mineral_name Text Recommended Name for mineral Examples are: San03-001
R Reclassified 11 Synthetic Material Name er_synthetic_name Text Recommended Name for synthetic material Examples are: STD1546-A1
X 12 Experiment Name magic_experiment_name Text Required Name for experiment Examples are: KOPA-299-1
F 13 Measurement Flag measurement_flag Flag Required Indicating if good (g) or bad (b) measurement Examples are: Default = g
F 14 Measurement Standard Flag measurement_standard Flag Required Indicating if a standard (s) or an unknown (u) measurement Examples are: Default = u
15 Measurement Number measurement_number Text Required Measurement identifier or lab number Examples are: 03C3012
16 Measurement Date and Time measurement_date Text Recommended Date and time of the measurement Examples are: Number in the "yyyy:mm:dd:hh:mm:ss.ss" format
17 Measurement Time Zone measurement_time_zone Text Recommended Time zone
18 Measurement Hysteresis Loop Number measurement_loop_x Integer Recommended Hysteresis loop: counter
19 Measurement Hysteresis Loop Total measurement_loop_n Integer Recommended Hysteresis loop: total number of loops
20 Measurement X Position measurement_pos_x Number in m Optional Position of the measurement relative to the specimen: x
21 Measurement Y Position measurement_pos_y Number in m Optional Position of the measurement relative to the specimen: y
22 Measurement Z Position measurement_pos_z Number in m Optional Position of the measurement relative to the specimen: z
23 Measurement Number of Positions measurement_positions Integer Recommended Number of different positions in measurement
24 Measurement Elevation measurement_elevation Number in m Recommended Measurement location: elevation relative to sealevel Examples are: Meters above sealevel
25 Measurement Stratigraphic Height measurement_height Number in m Recommended Measurement location: stratigraphic height Examples are: Positive is up in section or core, while negative is down relative to reference height
26 Measurement Drill Depth measurement_drill_depth Number in m Optional Measurement location: depth in MBSF as used by ODP Examples are: Meters below seafloor
27 Measurement Composite Depth measurement_composite_depth Number in m Optional Measurement location: composite depth in MBSF as used by ODP Examples are: Meters below seafloor
28 Lab Treatment Temperature treatment_temp Number in K Recommended Demagnetization temperature
29 Lab Treatment Temperature Decay Rate treatment_temp_decay_rate Number in K/s Optional Decay rate of temperature on cooling
30 Lab Treatment Temperature DC Field On treatment_temp_dc_on Number in K Optional Temperature in a pTRM experiment at which DC field is turned on
31 Lab Treatment Temperature DC Field Off treatment_temp_dc_off Number in K Optional Temperature in a pTRM experiment at which DC field is turned off
32 Lab Treatment AC Field treatment_ac_field Number in T Recommended Peak field in AC demagnetization experiment
33 Lab Treatment AC Field Decay Rate treatment_ac_field_decay_rate Number in T/s Optional Decay rate of AC field in AC field demagnetization experiment
34 Lab Treatment AC Field DC Field On treatment_ac_field_dc_on Number in T Optional AC field in a pARM experiment at which DC field is turned on
35 Lab Treatment AC Field DC Field Off treatment_ac_field_dc_off Number in T Optional AC field in a pARM experiment at which DC field is turned off
36 Lab Treatment DC Field treatment_dc_field Number in T Recommended Applied DC field
37 Lab Treatment DC Field Decay Rate treatment_dc_field_decay_rate Number in T/s Optional Decay rate of DC field after switching off
38 Lab Treatment DC Field AC Field On treatment_dc_field_ac_on Number in T Optional DC field in DC field experiment at which AC field is turned on
39 Lab Treatment DC Field AC Field Off treatment_dc_field_ac_off Number in T Optional DC field in DC field experiment at which AC field is turned off
40 Lab Treatment Orientation Phi treatment_dc_field_phi Number in Degrees Optional Orientation of sample in magnetometer
41 Lab Treatment Orientation Theta treatment_dc_field_theta Number in Degrees Optional Orientation of sample in magnetometer
42 Measurement Demagnetization Code measurement_demagn_code Text Optional Demagnitization code for legacy data
43 Measurement Temperature measurement_temp Number in K Recommended Temperature
44 Measurement Temperature Change measurement_temp_change Number in K Recommended Change in temperature during each measurement step
45 Measurement Frequency measurement_freq Number in Hz Recommended Frequency
46 Measurement Orientation Phi measurement_orient_phi Number in Degrees Recommended Orientation of sample in magnetometer
47 Measurement Orientation Theta measurement_orient_theta Number in Degrees Recommended Orientation of sample in magnetometer
48 Measurement Lab Field AC measurement_lab_field_ac Number in T Recommended Measured AC field in laboratory
49 Measurement Lab Field DC measurement_lab_field_dc Number in T Recommended Measured DC field in laboratory
50 Measurement Inclination measurement_inc Number in Degrees Recommended Directions in sample coordinates: inclination Examples are: Decimal degrees between -90 and 90
51 Measurement Declination measurement_dec Number in Degrees Recommended Directions in sample coordinates: declination Examples are: Decimal degrees between 0 and 360
52 Measurement Magnitude measurement_magnitude Dimensionless Recommended Uncalibrated magnitude measurement
53 Measurement Moment measurement_moment Number in Am2 Recommended Measured intensity: remanent moment
54 Measurement Magnetization Volume measurement_magn_volume Number in A/m Recommended Measured intensity: remanent magnetization that is volume normalized
55 Measurement Magnetization Weight measurement_magn_weight Number in Am2/kg Recommended Measured intensity: remanent magnetization that is weight normalized
56 Measurement Susceptibility K measurement_k Number in SI Recommended Magnetic susceptibility: volume normalized
57 Measurement Susceptibility X measurement_x Number in m3/kg Recommended Magnetic susceptibility: mass normalized
58 Measurement Susceptibility K Quadrature measurement_k_quadr Number in SI Optional Quadrature magnetic susceptibility: volume normalized
59 Measurement Susceptibility X Quadrature measurement_x_quadr Number in m3/kg Optional Quadrature magnetic susceptibility: mass normalized
60 Measurement Hysteresis Sweep Rate measurement_sweep_rate Number in T/s Recommended Rate of field sweep during a hysteresis loop measurement
61 Measurement Hysteresis Charging Mode measurement_charging_mode Text Recommended Measurement hysteresis charging mode Examples are: Hysteresis, Steady, No Overshoot
62 Measurement Goodness of Fit measurement_r2 Dimensionless Recommended Goodness of fit in regression Examples are: Number between 0 and 1
63 Measurement Circular Standard Deviation measurement_csd Number in Degrees Recommended Circular standard deviation in measurements Examples are: Uncertainty = 1xSD
64 Measurement Standard Deviation measurement_sd Number in Degrees Recommended Standard deviation in measurements Examples are: Uncertainty = 1xSD
65 Measurement Description measurement_description Text Optional Detailed description
R 66 Method Codes magic_method_codes Text Required Colon-delimited list of method codes Examples are: DE-DC0, FT-F1, LP-DCDMAG
R 67 Instrument Code magic_instrument_codes Text Required Colon-delimited list of instrument codes Examples are: SIO-Bubba, IRM-OldBlue
R 68 Analyst Names er_analyst_mail_names Text Required Colon-delimited list of names for analysts Examples are: Jim R.D. Hart, Alexis Heard, Bob McIntire
R 69 Citation Names er_citation_names Text Required Colon-delimited list of citations Examples are: Smith et al. 2003, Hart & Heard 1967, This study