In the pump and treat approach to the problem of managing a contaminated aquifer, a key problem is to design an effective capture system that collects only the polluted groundwater without allowing any of it to escape. At present, it is customary to design a capture system using fully penetrating withdrawal wells. Very often, however, only part of the vertical thickness of the aquifer is contaminated, so the question may arise whether a more efficient capture system can be achieved using partially penetrating wells. Very little work has been done on the application of partially penetrating wells to this problem. A new semianalytic method that can be used in determining the geometry of the capture zone for steady state flow to a partially penetrating well that is screened from the top (or from the bottom) of a confined aquifer has been developed. By combining the velocity potentials for flow to the well with that for the regional flow field, a three-dimensional velocity potential that can be used in determining the complete geometry of the capture surface has been developed. The results have shown that with a constant pumping rate the maximum horizontal extent of the capture surface at the top (or bottom) of the aquifer increases as the degree of penetration decreases. As one would expect, the maximum vertical extent increases as the depth of penetration increases. Thus, if one knows the actual location of the contaminant plume, an appropriate combination of the degree of penetration and pumping rate can be selected to create an effective capture zone. ¿ American Geophysical Union 1995 |